Taxation Ruling
TR 2011/2
Income tax: effective life of depreciating assets (applicable from 1 July 2011)
This version is no longer current. Please follow this link to view the current version. |
-
Please note that the PDF version is the authorised version of this ruling.This document has changed over time. View its history.
Effective lives (Industry Categories)
Table A as at 1 July 2011 - ELECTRICITY, GAS, WATER AND WASTE SERVICES
ELECTRICITY, GAS, WATER AND WASTE SERVICES
( 26110 to 29220 ) |
|||
Electricity supply
( 26110 to 26400 ) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Electricity distribution: | |||
Control, monitoring, communications and protection systems | 10 | * | 1 Jan 2002 |
Customer meters (incorporating load and time switches if fitted) | 25 | * | 1 Jan 2002 |
Customer service mains or cable, above ground | 40 | * | 1 Jan 2002 |
Customer service mains or cable, underground | 50 | * | 1 Jan 2002 |
Distribution lines: | |||
Above ground (incorporating conductors; cross arms, insulators and fittings; poles concrete, wood, steel or stobie; and transformers pole or ground pad mounted) | 45 | * | 1 Jan 2002 |
Combination of above ground and underground | 47 ½ | * | 1 Jan 2002 |
Underground (incorporating cables, fittings and ground pad mounted transformers) | 50 | * | 1 Jan 2002 |
Distribution substations/transformers, pole or ground pad mounted | 40 | * | 1 Jan 2002 |
Distribution zone substations (excluding control, monitoring, communications and protection systems) | 40 | * | 1 Jan 2002 |
Nightwatchman's lights | 15 | * | 1 Jan 2002 |
Street lights | 15 | * | 1 Jan 2002 |
Electricity generation: | |||
Ash and dust handling and disposal: | |||
Ash dams | 20 | * | 1 Jan 2002 |
Ash slurry system | 15 | * | 1 Jan 2002 |
Conveyors | 30 | * | 1 Jan 2002 |
Crushers | 15 | * | 1 Jan 2002 |
On-site storage silos, concrete or steel | 30 | * | 1 Jan 2002 |
Fuel supply and handling: | |||
On-site gaseous fuel supply system (incorporating downstream delivery pipelines) | 30 | * | 1 Jan 2002 |
On-site liquid fuel supply system (incorporating ownstream delivery pipelines) | 30 | * | 1 Jan 2002 |
Solid fuels: | |||
Coal handling assets (including conveyors, slot bunker, transfer towers, and weighers) | 30 | * | 1 Jan 2002 |
Day bunkers and silos, concrete or steel (incorporating top side conveyor system) | 30 | * | 1 Jan 2002 |
On-site coal storage assets (including stacking and reclaiming assets) | 30 | * | 1 Jan 2002 |
On-site storage silos, concrete or steel | 30 | * | 1 Jan 2002 |
Quality control assets (including coal sampling assets and secondary crushers) | 30 | * | 1 Jan 2002 |
Power generators: | |||
Co-generation: | |||
Condensing and feed heating assets | 30 | * | 1 Jan 2002 |
Control and monitoring system | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply assets) | 15 | * | 1 Jan 2002 |
Gas turbine generators | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in sub-tropical area | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in tropical area | 25 | * | 1 Jan 2002 |
Heat recovery steam generator | 30 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyard with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyard with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Reciprocating engine, diesel fired | 20 | * | 1 Jan 2002 |
Reciprocating engine, gas spark ignition | 20 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Steam turbine generator | 30 | * | 1 Jan 2002 |
Combined cycle: | * | 1 Jan 2002 | |
Condensing and feed heating assets | 30 | * | 1 Jan 2002 |
Control and monitoring system | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply assets) | 15 | * | 1 Jan 2002 |
Gas turbine generators | 30 | ||
Generator transformer and unit transformer in sub-tropical area | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in tropical area | 25 | * | 1 Jan 2002 |
Heat recovery steam generator | 30 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyard with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyard with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Steam turbine generator | 30 | * | 1 Jan 2002 |
Diesel or gas engine: | |||
Control and monitoring system | 15 | * | 1 Jan 2002 |
Diesel reciprocating engine | 20 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply assets) | 15 | * | 1 Jan 2002 |
Gas spark ignition reciprocating engine | 20 | * | 1 Jan 2002 |
Generator transformer and unit transformer in sub-tropical area | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in tropical area | 25 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyard with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyard with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Gas turbine: | |||
Control and monitoring system | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply assets) | 15 | * | 1 Jan 2002 |
Gas turbine generators | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in sub-tropical area | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in tropical area | 25 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyard with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyard with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Hydro-electric: | |||
Control and monitoring system | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply assets) | 15 | * | 1 Jan 2002 |
Generator transformer and unit transformer in sub-tropical area | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in tropical area | 25 | * | 1 Jan 2002 |
Hydro turbines and generators | 40 | * | 1 Jan 2002 |
Miscellaneous assets | 40 | * | 1 Jan 2002 |
On-site switchyard with conventional outdoor switchgear | 40 | * | 1 Jan 2002 |
On-site switchyard with gas insulated switchgear | 35 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 40 | * | 1 Jan 2002 |
Solar: | |||
Photovoltaic electricity generating system assets (incorporating photovoltaic panels, mounting frames and inverters) | 20 | * | 1 Jul 2011 |
Thermal: | |||
Condensing and feed heating assets | 30 | * | 1 Jan 2002 |
Control and monitoring system | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply assets) | 15 | * | 1 Jan 2002 |
Generator transformer and unit transformer in sub-tropical area | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in tropical area | 25 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyard with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyard with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Primary dust collection system (incorporating electrostatic precipitators or baghouse filters) | 30 | * | 1 Jan 2002 |
Solid fuel preparation assets (including fuel feeders and milling assets) | 30 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Steam generator | 30 | * | 1 Jan 2002 |
Steam turbine generator | 30 | * | 1 Jan 2002 |
Wind: | |||
Generator transformer and unit transformer in sub-tropical area | 30 | * | 1 Jan 2002 |
Generator transformer and unit transformer in tropical area | 25 | * | 1 Jan 2002 |
Wind turbine | 20 | * | 1 Jan 2002 |
Power station civil and structural works: | |||
Chimney stack: | |||
Concrete surround | 30 | * | 1 Jan 2002 |
Steel flues | 20 | * | 1 Jan 2002 |
Cooling tower, concrete or timber | 30 | * | 1 Jan 2002 |
Cooling water system (excluding cooling towers and condensing assets) | 30 | * | 1 Jan 2002 |
Power station buildings, to the extent that they form an integral part of plant | 30 | * | 1 Jan 2002 |
Workshop machinery and tools | 20 | * | 1 Jan 2002 |
Electricity transmission: | |||
Control, monitoring, communications and protection systems | 12 ½ | * | 1 Jan 2002 |
Power transformers | 40 | * | 1 Jan 2002 |
Transmission lines (incorporating conductors, insulators and towers) | 47 ½ | * | 1 Jan 2002 |
Transmission substations (excluding power transformers and control, monitoring, communications and protection systems) | 40 | * | 1 Jan 2002 |
Gas supply
( 27000 ) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Gas distribution: | |||
Control systems (excluding computers) | 10 | * | 1 Jul 2002 |
Gas meter | 15 | * | 1 Jul 2002 |
Low pressure (LP) gas storage holder | 40 | *# | 1 Jul 2002 |
Pigging device | 5 | * | 1 Jul 2002 |
Pipeline (including high, medium or low pressure trunk, primary or secondary mains or services): | |||
Generally | 50 | *# | 1 Jul 2002 |
PVC pipeline | 30 | *# | 1 Jul 2002 |
Regulators (including gate stations, subgate stations, block valve stations, pressure regulating stations and district regulating stations) | 40 | *# | 1 Jul 2002 |
Gas transmission: | |||
Compressor gas turbine (GT) driver | 20 | * | 1 Jul 2002 |
Compressor station assets | 30 | *# | 1 Jul 2002 |
Control systems (excluding computers) | 10 | * | 1 Jul 2002 |
Gas meter | 15 | * | 1 Jul 2002 |
Gas pipeline LNG station assets | 30 | *# | 1 Jul 2002 |
Pigging device | 5 | * | 1 Jul 2002 |
Pipeline - transmission, spur or lateral | 50 | *# | 1 Jul 2002 |
Regulators (including gate stations, subgate stations, block valve stations, pressure regulating stations and district regulating stations) | 40 | *# | 1 Jul 2002 |
Underground gas storage asset | 40 | *# | 1 Jul 2002 |
Irrigation water providers
( 28110 ) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Channel regulators | 80 | * | 1 Jan 2005 |
Cranes (including gantries) | 40 | * | 1 Jan 2005 |
Dams and weirs (incorporating gates and actuators) consisting of a barrier to obstruct the flow of water constructed from any or all of the following: concrete, earth and rockfill) | 100 | * | 1 Jan 2005 |
Drain inlet | 50 | * | 1 Jan 2005 |
Drainage channels (measured from the point of intersection with another drainage channel to the following intersection) | 100 | * | 1 Jan 2005 |
Escapes | 50 | * | 1 Jan 2005 |
Flow meters | 20 | * | 1 Jan 2005 |
Irrigation channels (incorporating siphons and subways) measured from offtake or regulator to regulator: | |||
Concrete | 50 | * | 1 Jan 2005 |
Earth | 80 | * | 1 Jan 2005 |
Measurement flumes | 50 | * | 1 Jan 2005 |
Metered outlets: | |||
Electronic | 40 | * | 1 Jan 2005 |
Mechanical | 50 | * | 1 Jan 2005 |
Piped | 40 | * | 1 Jan 2005 |
Offtakes | 80 | * | 1 Jan 2005 |
Pipes: measured from valve to valve, that are of the same age and same material (not being in the nature of a repair) | 80 | * | 1 Jan 2005 |
Pump inlets | 50 | * | 1 Jan 2005 |
Pump sets (incorporating switchboards, starters, motors and pumps) | 40 | * | 1 Jan 2005 |
Reservoirs and tanks | 80 | * | 1 Jan 2005 |
Valves | 40 | * | 1 Jan 2005 |
Water supply
( 28110 ) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Aerators and blowers | 20 | * | 1 Jan 2005 |
Cathodic protection systems | 20 | * | 1 Jan 2005 |
Chemical dosing pumps | 25 | * | 1 Jan 2005 |
Pump sets (incorporating switch boards, starters, motors and pumps) | 25 | * | 1 Jan 2005 |
Pressure reducing valves | 25 | * | 1 Jan 2005 |
Valves (excluding pressure reducing valves) | 30 | * | 1 Jan 2005 |
Raw water storage and supply assets: | |||
Bores | 30 | * | 1 Jan 2005 |
Dams and weirs | 100 | * | 1 Jan 2005 |
Dam or weir intake structures | 100 | * | 1 Jan 2005 |
Water treatment assets: | |||
Balance tanks | 80 | * | 1 Jan 2005 |
Bore water treatment assets: | |||
Aerators and blowers | 20 | * | 1 Jan 2005 |
Lime silos | 50 | * | 1 Jan 2005 |
Batching tanks | 80 | * | 1 Jan 2005 |
Lime pump sets (incorporating switch boards, starters, motors and pumps) | 25 | * | 1 Jan 2005 |
Reactors | 25 | * | 1 Jan 2005 |
Filtration tanks | 80 | * | 1 Jan 2005 |
Backwash pumps | 25 | * | 1 Jan 2005 |
Clear water tanks | 80 | * | 1 Jan 2005 |
Sludge thickeners | 50 | * | 1 Jan 2005 |
Drying beds | 50 | * | 1 Jan 2005 |
Chemical blowers | 15 | * | 1 Jan 2005 |
Chemical dosing systems | 15 | * | 1 Jan 2005 |
Chemical feeders and hoppers | 25 | * | 1 Jan 2005 |
Chemical mixers and blenders | 25 | * | 1 Jan 2005 |
Chemical storage tanks | 30 | * | 1 Jan 2005 |
Clarifiers (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Clear water tanks | 80 | * | 1 Jan 2005 |
Dissolved air flotation systems | 25 | * | 1 Jan 2005 |
Filtration tanks (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Flocculation tanks (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Inline mixers | 15 | * | 1 Jan 2005 |
Pen-stops | 25 | * | 1 Jan 2005 |
Raw water inlet screening systems | 25 | * | 1 Jan 2005 |
Sludge treatment lagoons | 50 | * | 1 Jan 2005 |
Wash water holding tanks | 80 | * | 1 Jan 2005 |
Water mains: Being lengths of trunk, distribution and reticulation mains within a section, measured from valve to valve that are of the same age and same material (not being in the nature of a repair) | 80 | * | 1 Jan 2005 |
Water supply pumping station detention tanks | 80 | * | 1 Jan 2005 |
Reservoirs, elevated tanks and standpipes: whether made from steel or concrete | 80 | * | 1 Jan 2005 |
Service connections: | |||
Water meters | 20 | * | 1 Jan 2005 |
Water supply control systems assets: | |||
Air scour flow meters, level sensors, transmitters and meters | 10 | * | 1 Jan 2005 |
Chlorine analysers, mini labs, PH meters, turbidity analysers and meters | 7 | * | 1 Jan 2005 |
Flow meters | 20 | * | 1 Jan 2005 |
Pressure sensors, transmitters and meters | 10 | * | 1 Jan 2005 |
Telemetry (including modems and remote transfer units) | 10 | * | 1 Jan 2005 |
Variable speed drives | 15 | * | 1 Jan 2005 |
Sewerage and drainage services
( 28120 ) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Chemical dosing pumps | 25 | * | 1 Jan 2005 |
Pump sets (incorporating switch boards, starters, motors and pumps) | 25 | * | 1 Jan 2005 |
Sewage service connection assets: | |||
Low pressure pumps | 25 | * | 1 Jan 2005 |
Vacuum pumps | 25 | * | 1 Jan 2005 |
Sewer mains: Being lengths of collection sewers measured from manhole to manhole (including branch, main, pressure, reticulation, sub-main and trunk sewers) (not being in the nature of a repair) | 80 | * | 1 Jan 2005 |
Pressure reducing valves | 25 | * | 1 Jan 2005 |
Valves (excluding pressure reducing valves) | 30 | * | 1 Jan 2005 |
Sewage pump station assets: | |||
Detention tanks | 80 | * | 1 Jan 2005 |
Overflow screens | 25 | * | 1 Jan 2005 |
Sewage treatment assets: | |||
Air filtration systems | 20 | * | 1 Jan 2005 |
Air scrubbers | 10 | * | 1 Jan 2005 |
Chemical blowers | 15 | * | 1 Jan 2005 |
Chemical feeders and hoppers | 25 | * | 1 Jan 2005 |
Chemical mixers and blenders | 25 | * | 1 Jan 2005 |
Chemical storage tanks | 30 | * | 1 Jan 2005 |
Pen-stops | 25 | * | 1 Jan 2005 |
Water storage tanks | 80 | * | 1 Jan 2005 |
Screenings removal assets | 25 | * | 1 Jan 2005 |
Grit removal assets | 25 | * | 1 Jan 2005 |
Primary treatment assets: | |||
Primary clarifiers (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Primary sedimentation lagoons | 50 | * | 1 Jan 2005 |
Primary sedimentation tanks (incorporating scrapers and weirs) | 80 | * | 1 Jan 2005 |
Scum collection and transfer systems | 25 | * | 1 Jan 2005 |
Secondary treatment assets: | |||
Biological nutrient removal (BNR) assets: | |||
Aerators and blowers | 20 | * | 1 Jan 2005 |
BNR tanks (incorporating mixed liquor stream, anoxic, anaerobic and swing zones and diffusers) | 80 | * | 1 Jan 2005 |
Mixers | 25 | * | 1 Jan 2005 |
Secondary clarifiers (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Secondary treatment lagoons | 50 | * | 1 Jan 2005 |
Secondary treatment tanks (incorporating scrapers and weirs) | 80 | * | 1 Jan 2005 |
Sequenced batch reactors | 80 | * | 1 Jan 2005 |
Sludge aerators and blowers | 80 | * | 1 Jan 2005 |
Tertiary treatment assets: | |||
Backwash air blowers | 20 | * | 1 Jan 2005 |
Chlorine contact tanks | 80 | * | 1 Jan 2005 |
Filtration tanks | 80 | * | 1 Jan 2005 |
Reverse osmosis assets: | |||
Fine screening systems | 15 | * | 1 Jan 2005 |
Micro filtration units | 15 | * | 1 Jan 2005 |
Reverse osmosis membrane filtration units | 10 | * | 1 Jan 2005 |
UV disinfectors | 25 | * | 1 Jan 2005 |
Sludge processing assets: | |||
Anaerobic digesters | 80 | * | 1 Jan 2005 |
Anaerobic digester gas handling and blowing systems | 25 | * | 1 Jan 2005 |
Anaerobic digester heating systems | 25 | * | 1 Jan 2005 |
Bio-filters | 80 | * | 1 Jan 2005 |
Dissolved air flotation systems | 25 | * | 1 Jan 2005 |
Lime disinfection dosing units | 25 | * | 1 Jan 2005 |
Sludge dewatering assets: | |||
Belt presses | 15 | * | 1 Jan 2005 |
Centrifuges | 20 | * | 1 Jan 2005 |
Screw conveyors | 25 | * | 1 Jan 2005 |
Screw presses | 20 | * | 1 Jan 2005 |
Sludge driers | 20 | * | 1 Jan 2005 |
Sludge heating units | 20 | * | 1 Jan 2005 |
Sludge thickening tanks (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Methane gas and cogeneration assets (see Electricity supply, 26100 and Gas supply, 27100) | |||
Dams: | |||
Lined earth dams | 100 | * | 1 Jan 2005 |
Dam covers | 20 | * | 1 Jan 2005 |
Effluent outfalls: | |||
Shoreline ocean | 100 | * | 1 Jan 2005 |
Extended ocean | 100 | * | 1 Jan 2005 |
River or estuary | 100 | * | 1 Jan 2005 |
Sewerage control systems assets: | |||
Chlorine residual analysers and PH meters | 7 | * | 1 Jan 2005 |
Dissolved oxygen probes, level sensors, transmitters and meters | 10 | * | 1 Jan 2005 |
Flow meters | 20 | * | 1 Jan 2005 |
Telemetry (including modems and remote transfer units) | 10 | * | 1 Jan 2005 |
Variable speed drives | 15 | * | 1 Jan 2005 |
Waste disposal services
( 29110 ) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Garbage compactor trucks (including the compactor) | 10 | * | 1 Jan 2005 |
CONSTRUCTION
( 30110 to 32990) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Air compressors: | |||
Compressors - reciprocating | 7 | * | 1 Jul 2008 |
Compressors - rotary screw | 10 | * | 1 Jul 2008 |
Backhoe loaders | 9 | * | 1 Jul 2002 |
Bending machines (bar, angle or rod) | 10 | * | 1 Jul 2008 |
Block and brick elevators (portable) | 10 | * | 1 Jul 2008 |
Chain blocks, rod shears, jacks, etc | 13 ⅓ | 1 Jan 2001 | |
Compaction: | |||
Compactors - flat plate | 8 | * | 1 Jul 2008 |
Compactors - vertical rammer | 6 | * | 1 Jul 2008 |
Concreting assets: | |||
Brick and paving saws | 5 | * | 1 Jul 2008 |
Concrete demolition saws | 3 | * | 1 Jul 2008 |
Concrete kibble buckets | 15 | * | 1 Jul 2008 |
Concrete mixers | 4 | * | 1 Jul 2008 |
Concrete surface preparation assets (including floor grinders, planers and scarifers) | 5 | * | 1 Jul 2008 |
Concrete trowels: | |||
Walk behind | 5 | * | 1 Jul 2008 |
Ride on | 7 | * | 1 Jul 2008 |
Concrete vibrating screeders | 5 | * | 1 Jul 2008 |
Concrete vibrators: | |||
Brushcutter style | 5 | * | 1 Jul 2008 |
Drive units | 6 | * | 1 Jul 2008 |
Flexible shaft pumps | 6 | * | 1 Jul 2008 |
Vibrating shaft | 3 | * | 1 Jul 2008 |
Concrete wheeled saws | 6 | * | 1 Jul 2008 |
Concreting plant: | |||
Batching plant: | |||
Portable and demountable | 6 ⅔ | 1 Jan 2001 | |
Static | 13 ⅓ | 1 Jan 2001 | |
Buggies or dumpers (motorised) | 5 | 1 Jan 2001 | |
Hoppers, skips and hoist buckets | 10 | 1 Jan 2001 | |
Mobile concrete pumping units | 6 ⅔ | 1 Jan 2001 | |
Cranes (mobile): | |||
Light and medium | 15 | * | 1 Jul 2002 |
Heavy (over 15.24 tonnes lift) | 20 | * | 1 Jul 2002 |
Tower and hoists | 10 | 1 Jan 2001 | |
Dozers/Front end loaders | 9 | * | 1 Jul 2002 |
Forklifts | 11 | * | 1 Jul 2002 |
Formwork, beams and props, steel | 10 | * | 1 Jul 2008 |
Hydraulic excavators | 10 | * | 1 Jul 2002 |
Levels: | |||
Dumpy | 7 | * | 1 Jul 2008 |
Laser beam | 10 | * | 1 Jul 2008 |
Lift slab assets (incorporating spreader bars, clutches, pulleys and cables) | 5 | * | 1 Jul 2008 |
Mini excavators | 8 | * | 1 Jul 2002 |
Motor graders | 10 | * | 1 Jul 2002 |
Pavers | 12 | * | 1 Jul 2002 |
Power supply assets: | |||
Generators, portable (incorporating attached engine management and generator monitoring instruments): | |||
Diesel | 10 | * | 1 Jul 2008 |
Petrol | 5 | * | 1 Jul 2008 |
Power tools: | |||
Chain saws | 3 | * | 1 Jul 2008 |
Hand tools: | |||
Air | 5 | * | 1 Jul 2008 |
Battery | 3 | * | 1 Jul 2008 |
Electric | 5 | * | 1 Jul 2008 |
Jack hammers: | |||
Air | 7 | * | 1 Jul 2008 |
Electric | 3 | * | 1 Jul 2008 |
Nail guns - air | 3 | * | 1 Jul 2008 |
Profilers | 10 | * | 1 Jul 2002 |
Pumps | 10 | 1 Jan 2001 | |
Road rollers | 15 | * | 1 Jul 2002 |
Saws, bench and mitre, portable | 7 | * | 1 Jul 2008 |
Scrapers | 8 | * | 1 Jul 2002 |
Skid steer loaders | 7 | * | 1 Jul 2002 |
Stabiliser recyclers | 12 | * | 1 Jul 2002 |
Telescopic handlers | 10 | * | 1 Jul 2002 |
Tool carriers | 10 | * | 1 Jul 2002 |
Track loaders | 9 | * | 1 Jul 2002 |
Traffic management assets (use the relevant lives given under Rental and hiring services (66110 to 66310), whether or not the assets are in fact hired or leased) | |||
Welders: | |||
Diesel | 10 | * | 1 Jul 2008 |
Electric | 5 | * | 1 Jul 2008 |
Wheel loaders | 8 | * | 1 Jul 2002 |
Winches | 13 ⅓ | 1 Jan 2001 |
Not issued as a draft
References
ATO references:
NO 99/132027; 2000/20567; 2003/11601; 2004/17815;
Related Rulings/Determinations:
IT 2685
TR 2000/18
TR 2006/5
TR 2006/15
TR 2007/3
TR 2008/4
TR 2009/4
TR 2010/2
Subject References:
Commissioner's determination of effective life
Commissioner's effective life schedule
decline in value
depreciating assets
depreciation
depreciation rates
effective life
self assessment of effective life
Legislative References:
ITAA 1997
ITAA 1997 Div 40
ITAA 1997 40-70(1)
ITAA 1997 40-72(1)
ITAA 1997 40-75(1)
ITAA 1997 40-95
ITAA 1997 40-100
ITAA 1997 40-100(4)
ITAA 1997 40-100(4)(b)
ITAA 1997 40-105(1)
ITAA 1997 40-110
ITAA 1997 Subdiv 40-B
ITAA 1997 Subdiv 40-E
ITAA 1997 Subdiv 40-F
ITAA 1997 Subdiv 40-G
ITAA 1997 40-520
ITAA 1997 40-555(1)
ITAA 1997 Subdiv 42-M
ITAA 1997 Div 43
ITAA 1997 Subdiv 328-D
TAA 1953
Tax Laws Amendment (Improvements to Self Assessment) Act (No. 2) 2005
Date: | Version: | Change: | |
You are here | 29 June 2011 | Consolidated ruling |