Taxation Ruling
TR 2019/5
Income tax: effective life of depreciating assets (applicable from 1 July 2019)
-
Please note that the PDF version is the authorised consolidated version of this ruling and amending notices.This Ruling, which applies from 1 July 2019, replaces TR 2018/4 (see paragraph 5 of this Ruling for further details).This document has changed over time. View its history.
Electricity, gas, water and waste services - (26110 to 29220)
ELECTRICITY, GAS, WATER AND WASTE SERVICES
(26110 to 29220) |
Electricity supply
(26110 to 26400) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Electricity distribution: | |||
Control, monitoring, communications and protection systems | 10 | * | 1 Jan 2002 |
Customer meters (incorporating load and time switches if fitted) | 25 | * | 1 Jan 2002 |
Customer service mains or cable, above ground | 40 | * | 1 Jan 2002 |
Customer service mains or cable, underground | 50 | * | 1 Jan 2002 |
Distribution lines: | |||
Above ground (incorporating conductors; cross arms, insulators and fittings; poles - concrete, wood, steel or stobie; and transformers - pole or ground pad mounted) | 45 | * | 1 Jan 2002 |
Combination of above ground and underground | 47 ½ | * | 1 Jan 2002 |
Underground (incorporating cables, fittings and ground pad mounted transformers) | 50 | * | 1 Jan 2002 |
Distribution substations/transformers, pole or ground pad mounted | 40 | * | 1 Jan 2002 |
Distribution zone substations (excluding control, monitoring, communications and protection systems) | 40 | * | 1 Jan 2002 |
Nightwatchman's lights | 15 | * | 1 Jan 2002 |
Street lights | 15 | * | 1 Jan 2002 |
Electricity generation: | |||
Ash and dust handling and disposal: | |||
Ash dams | 20 | * | 1 Jan 2002 |
Ash slurry systems | 15 | * | 1 Jan 2002 |
Conveyors | 30 | * | 1 Jan 2002 |
Crushers | 15 | * | 1 Jan 2002 |
On-site storage silos, concrete or steel | 30 | * | 1 Jan 2002 |
Fuel supply and handling: | |||
On-site gaseous fuel supply systems (incorporating downstream delivery pipelines) | 30 | * | 1 Jan 2002 |
On-site liquid fuel supply systems (incorporating downstream delivery pipelines) | 30 | * | 1 Jan 2002 |
Solid fuels: | |||
Coal handling assets (including conveyors, slot bunker, transfer towers, and weighers) | 30 | * | 1 Jan 2002 |
Day bunkers and silos, concrete or steel (incorporating top side conveyor system) | 30 | * | 1 Jan 2002 |
On-site coal storage assets (including stacking and reclaiming assets) | 30 | * | 1 Jan 2002 |
On-site storage silos, concrete or steel | 30 | * | 1 Jan 2002 |
Quality control assets (including coal sampling assets and secondary crushers) | 30 | * | 1 Jan 2002 |
Power generators: | |||
Co-generation: | |||
Condensing and feed heating assets | 30 | * | 1 Jan 2002 |
Control and monitoring system | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply (UPS) assets) | 15 | * | 1 Jan 2002 |
Gas turbine generators | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in sub-tropical areas | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in tropical areas | 25 | * | 1 Jan 2002 |
Heat recovery steam generators | 30 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyards with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyards with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Reciprocating engines, diesel fired | 20 | * | 1 Jan 2002 |
Reciprocating engines, gas spark ignition | 20 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Steam turbine generators | 30 | * | 1 Jan 2002 |
Combined cycle: | |||
Condensing and feed heating assets | 30 | * | 1 Jan 2002 |
Control and monitoring systems | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply (UPS) assets) | 15 | * | 1 Jan 2002 |
Gas turbine generators | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in sub-tropical areas | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in tropical areas | 25 | * | 1 Jan 2002 |
Heat recovery steam generators | 30 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyards with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyards with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Steam turbine generators | 30 | * | 1 Jan 2002 |
Diesel or gas engine: | |||
Control and monitoring systems | 15 | * | 1 Jan 2002 |
Diesel reciprocating engines | 20 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply (UPS) assets) | 15 | * | 1 Jan 2002 |
Gas spark ignition reciprocating engines | 20 | * | 1 Jan 2002 |
Generator transformers and unit transformers in sub-tropical areas | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in tropical areas | 25 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyards with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyards with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Gas turbine: | |||
Control and monitoring systems | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply (UPS) assets) | 15 | * | 1 Jan 2002 |
Gas turbine generators | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in sub-tropical areas | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in tropical areas | 25 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyards with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyards with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Hydro-electric: | |||
Control and monitoring system | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply (UPS) assets) | 15 | * | 1 Jan 2002 |
Generator transformers and unit transformers in sub-tropical area | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in tropical areas | 25 | * | 1 Jan 2002 |
Hydro turbines and generators | 40 | * | 1 Jan 2002 |
Miscellaneous assets | 40 | * | 1 Jan 2002 |
On-site switchyards with conventional outdoor switchgear | 40 | * | 1 Jan 2002 |
On-site switchyards with gas insulated switchgear | 35 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 40 | * | 1 Jan 2002 |
Solar: | |||
Photovoltaic electricity generating system assets (incorporating photovoltaic panels, mounting frames and inverters) | 20 | * | 1 Jul 2011 |
Thermal: | |||
Condensing and feed heating assets | 30 | * | 1 Jan 2002 |
Control and monitoring systems | 15 | * | 1 Jan 2002 |
Emergency power supply assets (including batteries and uninterruptible power supply (UPS) assets) | 15 | * | 1 Jan 2002 |
Generator transformers and unit transformers in sub-tropical areas | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in tropical areas | 25 | * | 1 Jan 2002 |
Miscellaneous assets | 30 | * | 1 Jan 2002 |
On-site switchyards with conventional outdoor switchgear | 30 | * | 1 Jan 2002 |
On-site switchyards with gas insulated switchgear | 30 | * | 1 Jan 2002 |
Primary dust collection systems (incorporating electrostatic precipitators or baghouse filters) | 30 | * | 1 Jan 2002 |
Solid fuel preparation assets (including fuel feeders and milling assets) | 30 | * | 1 Jan 2002 |
Station and auxiliary electrical systems within the power station | 30 | * | 1 Jan 2002 |
Steam generators | 30 | * | 1 Jan 2002 |
Steam turbine generators | 30 | * | 1 Jan 2002 |
Wind: | |||
Generator transformers and unit transformers in sub-tropical areas | 30 | * | 1 Jan 2002 |
Generator transformers and unit transformers in tropical areas | 25 | * | 1 Jan 2002 |
Wind turbines | 20 | * | 1 Jan 2002 |
Power station civil and structural works: | |||
Chimney stacks: | |||
Concrete surrounds | 30 | * | 1 Jan 2002 |
Steel flues | 20 | * | 1 Jan 2002 |
Cooling towers (concrete or timber) | 30 | * | 1 Jan 2002 |
Cooling water systems (excluding cooling towers and condensing assets) | 30 | * | 1 Jan 2002 |
Power station buildings, to the extent that they form an integral part of plant | 30 | * | 1 Jan 2002 |
Workshop machinery and tools | 20 | * | 1 Jan 2002 |
Electricity transmission: | |||
Control, monitoring, communications and protection systems | 12 ½ | * | 1 Jan 2002 |
Power transformers | 40 | * | 1 Jan 2002 |
Transmission lines (incorporating conductors, insulators and towers) | 47 ½ | * | 1 Jan 2002 |
Transmission substations (excluding power transformers and control, monitoring, communications and protection systems) | 40 | * | 1 Jan 2002 |
Gas supply
(27000) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Gas distribution [29] : | |||
Control systems (excluding computers) | 10 | * | 1 Jul 2002 |
Gas meters | 15 | * | 1 Jul 2002 |
Low pressure (LP) gas storage holders | 40 | *# | 1 Jul 2002 |
Pigging devices | 5 | * | 1 Jul 2002 |
Pipelines (including high, medium or low pressure trunk, primary or secondary mains or services): | |||
Generally | 50 | *# | 1 Jul 2002 |
Polyvinylchloride (PVC) pipelines | 30 | *# | 1 Jul 2002 |
Regulators (including gate stations, subgate stations, block valve stations, pressure regulating stations and district regulating stations) | 40 | *# | 1 Jul 2002 |
Gas transmission [30] : | |||
Compressor gas turbine (GT) drivers | 20 | * | 1 Jul 2002 |
Compressor station assets | 30 | *# | 1 Jul 2002 |
Control systems (excluding computers) | 10 | * | 1 Jul 2002 |
Gas meters | 15 | * | 1 Jul 2002 |
Gas pipeline LNG station assets | 30 | *# | 1 Jul 2002 |
Pigging devices | 5 | * | 1 Jul 2002 |
Pipelines - transmission, spur or lateral | 50 | *# | 1 Jul 2002 |
Regulators (including gate stations, subgate stations, block valve stations, pressure regulating stations and district regulating stations) | 40 | *# | 1 Jul 2002 |
Underground gas storage asset | 40 | *# | 1 Jul 2002 |
Water supply
(28110) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Assets used by irrigation water providers: | |||
Channel regulators | 80 | * | 1 Jan 2005 |
Cranes (including gantries) | 40 | * | 1 Jan 2005 |
Dams and weirs ((incorporating gates and actuators) consisting of a barrier to obstruct the flow of water constructed from any or all of the following:
concrete, earth and rockfill) |
100 | * | 1 Jan 2005 |
Drain inlet | 50 | * | 1 Jan 2005 |
Drainage channels (measured from the point of intersection with another drainage channel to the following intersection) | 100 | * | 1 Jan 2005 |
Escapes | 50 | * | 1 Jan 2005 |
Flow meters | 20 | * | 1 Jan 2005 |
Irrigation channels (incorporating siphons and subways) measured from offtake or regulator to regulator: | |||
Concrete | 50 | * | 1 Jan 2005 |
Earth | 80 | * | 1 Jan 2005 |
Measurement flumes | 50 | * | 1 Jan 2005 |
Metered outlets: | |||
Electronic | 40 | * | 1 Jan 2005 |
Mechanical | 50 | * | 1 Jan 2005 |
Piped | 40 | * | 1 Jan 2005 |
Offtakes | 80 | * | 1 Jan 2005 |
Pipes: measured from valve to valve, that are of the same age and same material (not being in the nature of a repair) | 80 | * | 1 Jan 2005 |
Pump inlets | 50 | * | 1 Jan 2005 |
Pump sets (incorporating switchboards, starters, motors and pumps) | 40 | * | 1 Jan 2005 |
Reservoirs and tanks | 80 | * | 1 Jan 2005 |
Valves | 40 | * | 1 Jan 2005 |
Assets used in water supply: | |||
Aerators and blowers | 20 | * | 1 Jan 2005 |
Cathodic protection systems | 20 | * | 1 Jan 2005 |
Chemical dosing pumps | 25 | * | 1 Jan 2005 |
Pump sets (incorporating switch boards, starters, motors and pumps) | 25 | * | 1 Jan 2005 |
Raw water storage and supply assets: | |||
Bores | 30 | * | 1 Jan 2005 |
Dam or weir intake structures | 100 | * | 1 Jan 2005 |
Dams and weirs | 100 | * | 1 Jan 2005 |
Reservoirs, elevated tanks and standpipes: whether made from steel or concrete | 80 | * | 1 Jan 2005 |
Service connections: | |||
Water meters | 20 | * | 1 Jan 2005 |
Valves: | |||
Generally | 30 | * | 1 Jan 2005 |
Pressure reducing valves | 25 | * | 1 Jan 2005 |
Water mains: being lengths of trunk, distribution and reticulation mains within a section, measured from valve to valve that are of the same age and same material (not being in the nature of a repair) | 80 | * | 1 Jan 2005 |
Water supply control systems assets: | |||
Air scour flow meters, level sensors, transmitters and meters | 10 | * | 1 Jan 2005 |
Chlorine analysers, mini labs, pH meters, turbidity analysers and meters | 7 | * | 1 Jan 2005 |
Flow meters | 20 | * | 1 Jan 2005 |
Pressure sensors, transmitters and meters | 10 | * | 1 Jan 2005 |
Telemetry (including modems and remote transfer units) | 10 | * | 1 Jan 2005 |
Variable speed drives (VSDs) | 15 | * | 1 Jan 2005 |
Water supply pumping station detention tanks | 80 | * | 1 Jan 2005 |
Water treatment assets: | |||
Balance tanks | 80 | * | 1 Jan 2005 |
Bore water treatment assets: | |||
Aerators and blowers | 20 | * | 1 Jan 2005 |
Backwash pumps | 25 | * | 1 Jan 2005 |
Batching tanks | 80 | * | 1 Jan 2005 |
Clear water tanks | 80 | * | 1 Jan 2005 |
Drying beds | 50 | * | 1 Jan 2005 |
Filtration tanks | 80 | * | 1 Jan 2005 |
Lime pump sets (incorporating switch boards, starters, motors and pumps) | 25 | * | 1 Jan 2005 |
Lime silos | 50 | * | 1 Jan 2005 |
Reactors | 25 | * | 1 Jan 2005 |
Sludge thickeners | 50 | * | 1 Jan 2005 |
Chemical blowers | 15 | * | 1 Jan 2005 |
Chemical dosing systems | 15 | * | 1 Jan 2005 |
Chemical feeders and hoppers | 25 | * | 1 Jan 2005 |
Chemical mixers and blenders | 25 | * | 1 Jan 2005 |
Chemical storage tanks | 30 | * | 1 Jan 2005 |
Clarifiers (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Clear water tanks | 80 | * | 1 Jan 2005 |
Dissolved air flotation systems | 25 | * | 1 Jan 2005 |
Filtration tanks (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Flocculation tanks (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Inline mixers | 15 | * | 1 Jan 2005 |
Penstocks | 25 | * | 1 Jan 2005 |
Raw water inlet screening systems | 25 | * | 1 Jan 2005 |
Sludge treatment lagoons | 50 | * | 1 Jan 2005 |
Wash water holding tanks | 80 | * | 1 Jan 2005 |
Sewerage and drainage services
(28120) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Chemical dosing pumps | 25 | * | 1 Jan 2005 |
Dams: | |||
Lined earth dams | 100 | * | 1 Jan 2005 |
Dam covers | 20 | * | 1 Jan 2005 |
Effluent outfalls: | |||
Shoreline ocean | 100 | * | 1 Jan 2005 |
Extended ocean | 100 | * | 1 Jan 2005 |
River or estuary | 100 | * | 1 Jan 2005 |
Methane gas and cogeneration assets - see Table A Electricity supply (26110 to 26400) and Gas supply (27000) | |||
Pump sets (incorporating switch boards, starters, motors and pumps) | 25 | * | 1 Jan 2005 |
Sewage pump station assets: | |||
Detention tanks | 80 | * | 1 Jan 2005 |
Overflow screens | 25 | * | 1 Jan 2005 |
Sewage service connection assets: | |||
Low pressure pumps | 25 | * | 1 Jan 2005 |
Vacuum pumps | 25 | * | 1 Jan 2005 |
Sewage treatment assets: | |||
Air filtration systems | 20 | * | 1 Jan 2005 |
Air scrubbers | 10 | * | 1 Jan 2005 |
Chemical blowers | 15 | * | 1 Jan 2005 |
Chemical feeders and hoppers | 25 | * | 1 Jan 2005 |
Chemical mixers and blenders | 25 | * | 1 Jan 2005 |
Chemical storage tanks | 30 | * | 1 Jan 2005 |
Grit removal assets | 25 | * | 1 Jan 2005 |
Penstocks | 25 | * | 1 Jan 2005 |
Screenings removal assets | 25 | * | 1 Jan 2005 |
Sludge processing assets: | |||
Anaerobic digesters | 80 | * | 1 Jan 2005 |
Anaerobic digester gas handling and blowing systems | 25 | * | 1 Jan 2005 |
Anaerobic digester heating systems | 25 | * | 1 Jan 2005 |
Bio-filters | 80 | * | 1 Jan 2005 |
Dissolved air flotation systems | 25 | * | 1 Jan 2005 |
Lime disinfection dosing units | 25 | * | 1 Jan 2005 |
Sludge dewatering assets: | |||
Belt presses | 15 | * | 1 Jan 2005 |
Centrifuges | 20 | * | 1 Jan 2005 |
Screw conveyors | 25 | * | 1 Jan 2005 |
Screw presses | 20 | * | 1 Jan 2005 |
Sludge driers | 20 | * | 1 Jan 2005 |
Sludge heating units | 20 | * | 1 Jan 2005 |
Sludge thickening tanks (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Treatment assets: | |||
Primary treatment assets: | |||
Primary clarifiers (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Primary sedimentation lagoons | 50 | * | 1 Jan 2005 |
Primary sedimentation tanks (incorporating scrapers and weirs) | 80 | * | 1 Jan 2005 |
Scum collection and transfer systems | 25 | * | 1 Jan 2005 |
Secondary treatment assets: | |||
Biological nutrient removal (BNR) assets: | |||
Aerators and blowers | 20 | * | 1 Jan 2005 |
BNR tanks (incorporating mixed liquor stream, anoxic, anaerobic and swing zones and diffusers) | 80 | * | 1 Jan 2005 |
Mixers | 25 | * | 1 Jan 2005 |
Secondary clarifiers (incorporating scrapers) | 80 | * | 1 Jan 2005 |
Secondary treatment lagoons | 50 | * | 1 Jan 2005 |
Secondary treatment tanks (incorporating scrapers and weirs) | 80 | * | 1 Jan 2005 |
Sequenced batch reactors | 80 | * | 1 Jan 2005 |
Sludge aerators and blowers | 80 | * | 1 Jan 2005 |
Tertiary treatment assets: | |||
Backwash air blowers | 20 | * | 1 Jan 2005 |
Chlorine contact tanks | 80 | * | 1 Jan 2005 |
Filtration tanks | 80 | * | 1 Jan 2005 |
Reverse osmosis assets: | |||
Fine screening systems | 15 | * | 1 Jan 2005 |
Micro filtration units | 15 | * | 1 Jan 2005 |
Reverse osmosis membrane filtration units | 10 | * | 1 Jan 2005 |
UV disinfectors | 25 | * | 1 Jan 2005 |
Water storage tanks | 80 | * | 1 Jan 2005 |
Sewerage control systems assets: | |||
Chlorine residual analysers and pH meters | 7 | * | 1 Jan 2005 |
Dissolved oxygen probes, level sensors, transmitters and meters | 10 | * | 1 Jan 2005 |
Flow meters | 20 | * | 1 Jan 2005 |
Telemetry (including modems and remote transfer units) | 10 | * | 1 Jan 2005 |
Variable speed drives (VSDs) | 15 | * | 1 Jan 2005 |
Sewer mains: Being lengths of collection sewers measured from manhole to manhole (including branch, main, pressure, reticulation, sub-main and trunk sewers) (not being in the nature of a repair) | 80 | * | 1 Jan 2005 |
Valves: | |||
Generally | 25 | * | 1 Jan 2005 |
Pressure reducing valves | 30 | * | 1 Jan 2005 |
Solid waste collection services
(29110) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Air compressors and receivers | 7 | * | 1 Jul 2015 |
Balers | 7 | * | 1 Jul 2015 |
Bins: | |||
Domestic mobile bins (plastic) | 10 | * | 1 Jul 2015 |
Industrial mobile rubbish bins (metal) | 8 | * | 1 Jul 2015 |
Industrial mobile rubbish bins (plastic) | 5 | * | 1 Jul 2015 |
Metal skips for hire | 8 | * | 1 Jul 2015 |
Roll-on roll-off containers | 10 | * | 1 Jul 2015 |
Stationary and portable compactor bins | 8 | * | 1 Jul 2015 |
Bin delivery vehicle cranes/bin and skip lifters | 10 | * | 1 Jul 2015 |
Compactors and collection bodies on trucks (including lifting arms) | 8 | * | 1 Jul 2015 |
Fans | 10 | * | 1 Jul 2015 |
Forklifts | 11 | * | 1 Jul 2015 |
Garbage compactor trucks (excluding the compactor) [31] | 10 | *# | 1 Jul 2015 |
Hook lifts on truck body | 10 | * | 1 Jul 2015 |
Truck hoists | 20 | * | 1 Jul 2015 |
Washing assets (including pressure washers) | 4 | * | 1 Jul 2015 |
Waste water treatment systems | 10 | * | 1 Jul 2015 |
Waste treatment and disposal services
(29210) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Transfer stations and landfill operation assets: | |||
Air compressors and receivers | 7 | * | 1 Jul 2015 |
Balers | 7 | * | 1 Jul 2015 |
Bins: | |||
Bins generally (including metal bins) | 7 | * | 1 Jul 2015 |
Compactor bins | 6 | * | 1 Jul 2015 |
Mobile bins (including rubbish bins) | 5 | * | 1 Jul 2015 |
Bulk fuel above ground tanks | 20 | * | 1 Jul 2015 |
Bulldozers and drotts (including landfill compaction assets) | 5 | * | 1 Jul 2015 |
CCTV and security systems | 4 | * | 1 Jul 2015 |
Concrete crushing assets | 15 | 1 Jul 2015 | |
Dust and odour control assets | 12 | * | 1 Jul 2015 |
Excavators and front end loaders | 5 | * | 1 Jul 2015 |
Fans | 10 | * | 1 Jul 2015 |
Forklifts used in waste handling | 5 | * | 1 Jul 2015 |
Forklifts not used in waste handling | 11 | * | 1 Jul 2015 |
Gas capture assets: | |||
Extraction assets (including wells, laterals and headers, and condensate systems) | 8 | * | 1 Jul 2015 |
Flare skid assets generally (including blowers, monitoring systems and flame arresters, but excluding flare stacks) | 7 ½ | * | 1 Jul 2015 |
Flare stacks - continuous use | 15 | * | 1 Jul 2015 |
Flare stacks - standby stacks | 7 ½ | * | 1 Jul 2015 |
Monitoring systems (excluding wells) | 5 | * | 1 Jul 2015 |
Off-site monitoring wells | 15 | * | 1 Jul 2015 |
Green waste mulchers and shredders | 7 | * | 1 Jul 2015 |
Hoppers | 7 | * | 1 Jul 2015 |
Push pits | 15 | * | 1 Jul 2015 |
Sweepers - road sweepers | 10 | * | 1 Jul 2015 |
Transfer trailers | 10 | * | 1 Jul 2015 |
Water treatment systems | 10 | * | 1 Jul 2015 |
Weighbridges | 15 | * | 1 Jul 2015 |
Waste remediation and materials recovery services
(29220) |
|||
ASSET |
LIFE
(YEARS) |
REVIEWED |
DATE OF
APPLICATION |
Materials recovery facility (MRF) assets: | |||
Air compressors and receivers | 7 | * | 1 Jul 2014 |
Balers | 7 | * | 1 Jul 2014 |
Ballistic separators | 10 | * | 1 Jul 2014 |
Bins: | |||
Bins generally (including metal bins) | 7 | * | 1 Jul 2014 |
Compactor bins | 6 | * | 1 Jul 2014 |
Mobile bins (including rubbish bins) | 5 | * | 1 Jul 2014 |
Bunkers | 10 | * | 1 Jul 2014 |
CCTV and security systems | 4 | * | 1 Jul 2014 |
Chippers and shredders | 7 | * | 1 Jul 2014 |
Control systems | 10 | * | 1 Jul 2014 |
Conveyors and conveyor systems: | |||
Bounce conveyors and feeders | 10 | * | 1 Jul 2014 |
Conveyors generally ((incorporating belt, drive, motors and supporting structure) including walking floor conveyors) | 9 | * | 1 Jul 2014 |
Hand sort conveyors | 10 | * | 1 Jul 2014 |
Door controls and motor drive systems for automatic opening doors (incorporating controls, motors and sensors, but excluding doors) | 10 | * | 1 Jul 2014 |
Ducted air transfer system assets | 10 | * | 1 Jul 2014 |
Dust collectors | 12 | * | 1 Jul 2014 |
Eddy current separators | 7 | * | 1 Jul 2014 |
Excavators and front end loaders | 5 | * | 1 Jul 2014 |
Fans | 10 | * | 1 Jul 2014 |
Feed hoppers (incorporating steel drag chain, conveyor belt, metering feed roller, motor and gearbox) | 5 | * | 1 Jul 2014 |
Ferrous and magnetic separators | 10 | * | 1 Jul 2014 |
Food separation and screening assets | 10 | * | 1 Jul 2014 |
Forklifts | 5 | * | 1 Jul 2014 |
Glass breakers and crushers | 6 | * | 1 Jul 2014 |
Hoppers | 7 | * | 1 Jul 2014 |
Leachate pumps and filters | 10 | * | 1 Jul 2014 |
Lifting assets (including pallet jacks) | 10 | * | 1 Jul 2014 |
Optical sorters | 5 | * | 1 Jul 2014 |
Screen separators | 10 | * | 1 Jul 2014 |
Sweepers and scrubbers | 10 | * | 1 Jul 2014 |
Trommels (incorporating wheels, motors and gearboxes): | |||
Fixed | 7 | * | 1 Jul 2014 |
Portable | 7 | * | 1 Jul 2014 |
Vacuum extraction and cleaning assets | 10 | * | 1 Jul 2014 |
Vibrating screen separators | 10 | * | 1 Jul 2014 |
Waste compactors | 9 | * | 1 Jul 2014 |
Weighbridges | 15 | * | 1 Jul 2014 |
Not previously issued as a draft
References
ATO references:
NO 1-HHM96UX
Previous Rulings/Determinations:
TR 2013/4
TR 2014/4
TR 2015/2
TR 2016/1
TR 2017/2
TR 2018/4
Subject References:
depreciation
depreciation rate
effective life
Legislative References:
ITAA 1997
ITAA 1997 Div 40
ITAA 1997 40-25
ITAA 1997 40-70(1)
ITAA 1997 40-72(1)
ITAA 1997 40-75(1)
ITAA 1997 40-95
ITAA 1997 40-95(4)
ITAA 1997 40-95(5)
ITAA 1997 40-95(7)
ITAA 1997 40-100
ITAA 1997 40-100(5)
ITAA 1997 40-100(6)(b)
ITAA 1997 40-102
ITAA 1997 40-102(4)
ITAA 1997 40-102(4A)
ITAA 1997 40-105
ITAA 1997 40-110
ITAA 1997 40-345(2)
TAA 1953
Other References:
Income Tax (Effective Life of Depreciating Assets) Amendment Determination 2019 (No. 1)
Date: | Version: | Change: | |
26 June 2019 | Original ruling | ||
You are here | 22 April 2020 | Consolidated ruling |